Solitron manufactures standard transistor products in accordance with MIL-PRF-19500. We can also build to customer source control documents or customized screening travelers.
Screening Method | Electrical Only | Commercial & COTS | MIL-PRF-19500 | JAN "S" |
---|---|---|---|---|
Stabilization Bake MIL-STD 750 Method 1032 | NO | NO | Maximum Operating Temperature 340 hours | Maximum Operating Temperature 340 hours |
Temperature Cycle MIL-STD 750 Method 1051 | NO | NO | 20 Cycles @ -55°C to + 175°C | 20 Cycles @ -55°C to + 175°C |
Surge MIL-STD 750 Method 4066 | NO | NO | Sinusoidal Current Surge | Sinusoidal Current Surge |
Thermal Impedance MIL-STD 750 Method 3161 | NO | NO | Delta Source Drain Voltage Method | Delta Source Drain Voltage Method |
Constant Acceleration MIL-STD 750 Method 2006 | NO | NO | Y Axis 20,000 G?s | Y Axis 20,000 G?s |
PIND Test MIL-STD 750 Method 2052 | NO | NO | 20 G / 40 to 250Hz | 20 G / 40 to 250Hz |
Fine Leak Test MIL-STD 750 Method 1071 Helium Tracer Gas atm cm/3 or greater | Condition H 60 PSI pressurization for 4 hours 1X10-9 | Condition H 60 PSI pressurization for 4 hours 1X10-9 | Condition H 60 PSI pressurization for 4 hours 1X10-9 | Condition H 60 PSI pressurization for 4 hours 1X10-9 |
Gross leak Test MIL-STD 750 Method 1071 Flourocarbon | Condition C 60 PSI pressurization for 8 hours | Condition C 60 PSI pressurization for 8 hours | Condition C 60 PSI pressurization for 8 hours | Condition C 60 PSI pressurization for 8 hours |
Interim Electrical Test | 25°C, + 125°C | 25°C, + 125°C | 25°C, 125°C, -55°C | 25°C, 125°C, -55°C |
HTRB MIL-STD 750 Method 1042 80 percent of rated drain to source voltage Steady State Gate bias. | NO | Condition A/B Steady State reverse bias/ 48 hours | Condition A/B Steady State reverse bias/ 160 hours | Condition A/B Steady State reverse bias/ 160 hours |
Post HTRB Electrical (Delta/PDA) | NO | Within 96 hours | Within 24 hours | Within 16 Hours |
Burn In MIL-STD 750 Method 1039 Maximum rated power | NO | 48 Hours | 160 Hours | 240 Hours |
Final Electrical | 25°C, 125°C | 25°C, 125°C | 25°C, 125°C, and -55°C | 25°C, 125°C and -55°C |
Radiographic Inspection Mil 750 Method 2076 | NO | NO | NO | 100 percent |